Effort Semiconductor Lighting Ltd.

Effort Semiconductor Lighting Ltd.

News

  • Product History
    Since the establishment of Effort, the products have also gone through generations of upgrades.

    2023 05/25

  • Latest updates on emergency lighting standard EN60598-2-22
    On September 27, 2020, the EU released a new version of the emergency lighting standard: EN 60598-2-22:2014/A1:2020 New standard release date: September 27, 2020 Old standard expiration date: March 27, 2023 Standard update content Definitions • Added practical emergency light source luminous flux definition (PELSF): The minimum luminous flux of the light source observed during the rated duration of emergency mode. Optical test requirements • Manufacturers shall provide intensity distribution data calculated according to ISO 30061 for the emergency lighting device. The luminous intensity in emergency mode can be expressed in cd or cd/1000lm. If expressed in cd, the manufacturer shall also provide the rated luminous flux derived from the light distribution curve table. • If expressed in cd/1000 lm, the manufacturer shall provide the reference luminous flux in emergency mode. For luminaires with tubular fluorescent lamps or other discharge lamps, the reference luminous flux is the actual emergency light source luminous flux PELF multiplied by the EBLF of the associated emergency gear. For luminaires with LED light sources, the reference luminous flux is: the actual emergency light source luminous flux PELS, which can be calculated as: LED module (LDL) luminous flux under reference conditions corresponding to the luminaire (at the same TP) and at rated current (normal mode) multiplied by the EOFI (emergency/non-maintained mode) of the associated emergency control device. • Emergency lighting luminaires shall provide at least 50% of the luminous intensity data claimed by the manufacturer for emergency mode within 5 seconds of a normal power supply failure; and 100% of the rated luminous intensity performance within 60 seconds until the end of the rated emergency operating duration. Emergency lighting luminaires for use in high risk task area lighting shall provide 100% of the claimed luminous intensity data within 0.5 seconds of a normal power supply failure and continue until the end of the rated emergency operating time.

    2022 04/25

  • Effort is the brand name of Ningbo Rontek Electronics Co., Ltd, established in 2010 and located in Ningbo.

    2020 05/25

  • 3.2H42A------2019 Guangzhou Lighting Fair
    Warmly welcome to visit Effort at 3.2H42A on June 9-12th of Emergency Battery Pack & Emergency Luminaires.

    2019 09/12

  • 2018 HK Lighting Fair
    2018 HK Lighting Fair5E-H27,On OCT. 27th-30th Self test Emergency Converter,self test Emergency Light & Wireless System for Emergency Light.,widely used on all products.

    2018 10/27

  • 2018 Guangzhou International Lighting Fair
    2018 Guangzhou International Lighting Fair Explore Self test Emergency Converter& self test Emergency Light.

    2018 09/12

Total 6 News

Email to this supplier

-